- Battery Type: Maintenance-free sealed Lead-Acid battery with suspended electrolyte: LeakProof- Replacement Battery: RBC17- RBC count: 1- Runtime Chart: Back-UPS CS- Front panel LED status display with On Line: On Battery: Replace Battery and Overload indicators- Audible Alarm: Alarm when on battery: distinctive low battery alarm: overload continuous tone alarm- Nominal Input Voltage: 230V- Input Frequency: 50/60 Hz +/- 3 Hz (auto sensing)- The maximum power that can be configured: 650 VA- The maximum power that can be configured: 400 watts
- Degree of protection IP20- Designed for office / industrial premises with low pos. pollution- Built-in cooling fans- Input: 230V AC 50Hz (178 ~ 281V AC)- Output: 230V AC 50Hz (195 ~ 253V AC)- Battery back time (80/50%): 4/7 minutes- Maximum output cable length:
- Output Power 240 W / 400 VA- The maximum power that can be configured: 240 W / 400 VA- Output voltage: 230V- Output Frequency (sync to mains): 47 - 63 Hz- Crest Factor 3: 1- Waveform Type: Stepped approximation to a sinewave- Front panel: LED indicates the status of the power supply: Power supply from the mains: On Battery- Audio Alarm: when using the battery: distinctive low battery alarm: steady tone alarm overload- Surge energy (in Joules): 310- Filtering: Full time multi-pole noise filtering: 5% IEEE surge let-through: zero clamping response time: meets UL 1449- Data Line Protection RJ-45 Modem / Fax / DSL 10-100 Base-T
- Output Power: 800W- Output voltage: 230V- Distortion of the output voltage
- Output Power Capacity: 600 Watts- Nominal Output Voltage: 230V- Output Voltage Distortion: Less than 5%- Waveform Type: Sine wave- Output Connections: (2) IEC Jumpers - Available SmartSlot™ Interface Quantity: 1- Surge energy rating: 645 Joules
-Input voltagewithout the use ofbatteries:160-294V,47-70Hz-Output voltage:200/208/220/230 /240V,50/60Hz-Twogroups of outlets2 xIECC13(10A) remote-controlled- Automaticbattery test-1card slotCommunicationNetwork-MS,ModBus-MS,MS-Relay-1miniterminal blockforremote on./ Off.and theRemote Emergency Power Off
-Output Power:300W-Input voltage:190-259V+-5%-Output voltage:190-259V+-5%-Switching thresholds:network/ UPS:190/259V+-5%-Back-up time(80%/50%Pmax):3/8min-Signalling:acousto-optics;LCD display- Automaticfuse
-Safety:IEC/ EN62040-1, AS62040.1.1, AS62040.1.2-EMC: IEC/ EN62040-2, AS62040.2-Product Certification: CE,RCM(E2376)
- Degree of protection: IP20- Working environment: office / industrial areas with low pollution levels- Cooling: internal fans- Input: 230V 50Hz (178 ~ 281V AC 45/55 Hz)- Output: 230V 50Hz (195 ~ 253V AC 50 Hz)- Maintenance (80/50%): 4/6 minutes- Signaling: acoustic-optical- 3 controllable C13 10A output connectors
- Degree of protection: IP20- Working environment: office / industrial areas with low pollution levels- Cooling: internal fans- Input: 230V 50Hz (178 ~ 281V AC 45/55 Hz)- Output: 230V 50Hz (195 ~ 253V AC 50 Hz)- Maintenance (80/50%): 4/8 minutes- Signaling: acoustic-optical- 3 controllable C13 10A output connectors
-Power:480W-Input voltage:220/230/240VAC-The range ofinput voltage:170-280VAC+-7%-Output voltage:220/230/240VAC+-10%;50 /60Hz+-1Hz
-Signalling:acoustic/optical- Fuse: automatic-ActiveOutput Power: 600WWorking withthe network:-Input voltage:~190 -259V ± 5%- FrequencyInput voltage:45 -55Hz± 1HzWorking withbattery:-Shape of output voltage:Steppedapproximation to asine wave-Frequency of output voltage50Hz± 1Hz
Certifications: EN 62040-1, EN 62040-2, EN 62040-3DAKER DK+ is managed by a microprocessor and is able to manage alarms and other functions described below via the control panel and LCD display:Normal workThe output frequency is not synchronized with the inputWork on the batteryWork in Bypass modeDamaged power moduleOverloadGeneral anomalyNeutral connection with the groundEnd of autonomy
Certifications: EN 62040-1, EN 62040-2, EN 62040-3DAKER DK + is managed by a microprocessor and is able to manage alarms and other functions described below via the control panel and LCD display:Normal workThe output frequency is not synchronized with the inputWork on the batteryWork in Bypass modeDamaged power moduleOverloadGeneral anomalyNeutral connection with the groundEnd of autonomy
Confirmation of CE conformity
Confirmation of conformity CE, CSA, EAC, EN / IEC 62040-1, EN / IEC 62040-2, RCM, UL 1778, VDE
- CD with software- Documentation CD- Installation guide- Rack Mounting brackets- Removable support feet- Smart UPS signalling RS-232 cable- USB cable
- CD with software- Documentation CD- Installation guide- Rack Mounting brackets- Removable support feet- Smart UPS signalling RS-232 cable- User Manual
- CD with software- Documentation on CD- 2 x Detachable IEC C13 power cables to IEC C14, USB cable
- CD with software- Signalization cable RS-232 for Smart-UPS- User manual
- User's guide
-UPSPowerWalkerVI850SE- USB cable-Software CD- User manual
Podręcznik użytkownika
- DPC system - Digital Power Control- Cold start – the possibility of starting the device without connection to the mains;- Telecommunication filter- Convenient switch- Four IEC 320 outlet sockets emergency power supply- Synchronization with the mains- Sound indication of discharged battery- Resistance to overload resistance- Short circuit protection- USB interface
- EPO - High online efficiency - Green mode - High frequency design - Energy meter - Predictive replace battery date - Intuitive LCD interface - Auto recognition of external batteries - Multiple switched outlet groups - Pure sine wave output on battery - Scalable runtime - Cold-start capable - Plug-and-Play external batteries - Rack/Tower convertible - SmartSlot - Temperature-compensated battery charging - Boost and Trim Automatic Voltage Regulation (AVR)- Intelligent battery management- Power conditioning- Temperature-compensated battery charging- Automatic restart of loads after UPS shutdown- Automatic self-test- Disconnected battery notification- Network manageable- Audible alarms- LED status indicators- Serial connectivity- USB connectivity- Disconnected battery notification- User-replaceable batteries- Hot-swappable batteries- Predictive failure notification- Resettable circuit breakers- Battery failure notification- Adjustable voltage-transfer points- Adjustable voltage sensitivity- Safety-agency approved
- EPO - High online efficiency - Green mode - High frequency design - Energy meter - Predictive replace battery date - Intuitive LCD interface - Auto recognition of external batteries - Single switched outlet group - Multiple switched outlet groups - Pure sine wave output on battery - Scalable runtime - Cold-start capable - Plug-and-Play external batteries - Rack/Tower convertible - SmartSlot - Temperature-compensated battery charging - Boost and Trim Automatic Voltage Regulation (AVR)- Intelligent battery management- Power conditioning- Temperature-compensated battery charging- Automatic restart of loads after UPS shutdown- Automatic self-test- Disconnected battery notification- Network manageable- Audible alarms- LED status indicators- Serial connectivity- USB connectivity- Disconnected battery notification- User-replaceable batteries- Hot-swappable batteries- Predictive failure notification- Resettable circuit breakers- Battery failure notification- Adjustable voltage-transfer points- Adjustable voltage sensitivity- Safety-agency approved
- Rack / Tower housing- Voltage regulation system AVR (boost and lower)- Graphical LCD display- Battery charging system with thermal compensation- Predictive hold time- Cold start- Battery replacement by the user- Network interface as standard (SNMP / HTTP)- HID USB communication interface- Firmware update (by user)
- Reduced charging time- Excellentmicroprocessor controlguarantees highreliability- Built in Automatic Voltage Regulation (AVR)- Simulated Sine- Automatic reboot after power is back- Charging while on- Cold start function- USB port- RJ-11 protection- Energy saving function (can be turned off)
- "Cold start"-EnhancedLCD panel(EVS)-Soundsignalingcertain operating conditions- Digitalmonitoring ofthe battery charge level(DBM)-Intelligentmulti-function button(IMB)-Microprocessor parameter control-Dual Protection System(DPS)-Power saving mode(GREENFUNCTION)-Quick and easyreplacement ofbeterii(ESB)- FilterICT(RJ45)
-Graphic LCD display (7 languages)-Energy efficiencyup to 98%-Energy measurement-Discontinuouscharging-Switchablegroup ofoutlets-Sinusoidalwaveformoutput-Multiplecommunication options(compatiblewithvirtual environments)- Warranty3 yearselectronics, 2 yearsonbatteries
- Output power equal to apparent power (PF = 1)- Rack / Tower mounting- Voltage regulation system AVR (boost and lower)- Graphical LCD display- Battery charging system with thermal compensation- Predictive hold time- Ability to manage output sockets- Cold start- Battery replacement by the user- Support for external battery module (optional)- EPO input support (optional)- Network interface as standard (SNMP, HTTP)- HID USB communication interface- RS232 / RS485 communication interface (MODBUS) (optional)- Support for potential-free outputs and control inputs (optional)- LAN filter (1 Gb / s)- Firmware update by user
LCD display
EPO
EPOParallel connectionOutput sockets: 8x IEC C13, 2x IEC C19
- Operating Environment: 0 - 40 °C- Operating Relative Humidity: 0 - 95%- Operating Elevation: 0-3000 meters- Storage Temperature: -15 - 45 °C- Storage Relative Humidity: 0 - 95%- Storage Elevation: 0-15000 meters- Audible noise at 1 meter from surface of unit: 40.00 dBA- Online Thermal Dissipation: 69.00 BTU/hr
- Operating Environment: 0 - 45 °C- Operating Relative Humidity: 0 - 95%- Operating Elevation: 0-3000 meters- Storage Temperature: -15 - 45 °C- Storage Relative Humidity: 0 - 95%- Storage Elevation: 0-15000 meters- Audible noise at 1 meter from surface of unit: 40.00 dBA- Online Thermal Dissipation: 82.00 BTU/hr
- Operating environment: 0 - 40 ° C- Operating relative humidity 0 - 95%- Height above sea level operating: 0-15000 meters- Temperature (TT): 0 - 40 ° C- Relative humidity (storage): 0 - 95%- Height above sea level (storage): 0-15000 meters- Audible noise at 1 meter from surface of unit: 45.00 dBA- Thermal dissipation 30.00 BTU/hr
- Operating temperature 0 - 40°C- Relative humidity during operation 0 - 90%- Height during operation 0-1968.3metres- Noise heard at a distance of 1 m from the surface of the device 40.0dBA
-Operating Temperature: 0 to35 degreesC-Noise level:<40dBA
-Operating Temperature:10 -35 degreesC-Storage Temperature:0-45 degreesC-Relative humidityof work/storage:20-80%/20-95%(non-condensing)-Heightn.p.m.:1,000m-Max.length of theoutput:<10m
- Working temperature: 0 - 40 degrees Celsius- Storage temperature: 0 to 45 degrees C- Operating humidity: 20 - 80% (non-condensing)- Storage Ambient Humidity: 20 - 95% (non-condensing)- Height up to 1000 m
-Ambient temperature: 0 to40°C-Humidity:0 to90%
-Working environment:officesor industrial rooms withlow level of pollution-Operating temperature: 10 to35 °C.- Storage temperature: 0 to45 °C-Relative humidityduring operation:20-80%-Relative humidityduring storage:20-95%-Heightn.p.m:up to 1000 m
Temperature during operation: 0-40°C
Working temperature 0-40°CDegree of protection IP 21Working humidity 20-80%Sound intensity at a distance of 1m
Software:WinPower- Abilityto controlandmonitor multipleUPS unitsfrom the local networkand the Internet-Chartspower analysis,eventstatistics, exportdata history-Data GraphUPS unitsin real time (voltage, frequency,load level,battery level)- SafeShutdownandprotection of data againstpower failure- Notificationsusing thesystem sounds, e-mail, SMS,to all the computerson the LAN- Scheduleon / off, battery test, programmablecontrolsocket,controlaudible alarms.-Optional passwordprotection, remote accessandmanagement-Support multiplelanguages: English, Chinese, French, German, Spanish,Russian, Portuguese, Ukrainian, Italian,Polish, Czech,Turkish-Operating system: Windows/Mac/ Linux/ Unix/Solaris/AJX/ HP-UX/FreeBSD-http://www.powerwalker.com/winpower.html
Monitoring andManagement
PowerSoft monitoring and management software
PowerSoft
PowerSoft Personal
PowerSoft Professional
PowerSoft Professional monitoring and management software
WinPower
YES - for downloading from the site: http://ups.legrand.pl/software/
- Height: 89 mm- Width: 432 mm- Depth: 490 mm- Rack Height 2U
- Maximum Height: 165.00 mm- Maximum width: 91.00 mm- Maximum Depth: 284.00 mm
- Maximum height: 168.00 mm- Maximum width: 119.00 mm- Maximum depth: 375.00 mm
- Rack 132 x 440 x 460 mm (mounting kit available optional)- Tower (+ stands): 450 x 304 x 460 mm
84 x 174 x 280
88 (2U) x 438 x 610 mm
88 x 485 x 200 mm
91.5 H x 158 W x 240 D mm
92mm x 160mm x 305mm
100 x 250 x 382 mm
143 x 100 x 290 mm
145 x 345 x 165 mm
150 x 90 x 434 mm
158 x 84 x 252 mm
165 x 91 x 284 mm
219 x 171 x 439 mm
230 x 258 x 86 mm
244 x 575 x 542 mm
258 x 84 x 358 mm
279 x 100 x 143 mm
288 x 148 x 100 mm.
298x101x142mm
310 x 685 x 941 mm
380x158x198mm
438 x 436 x 86.5 mm
440 x 88 x 405 mm
440 x 176 (4U) x 680 mm
575 x 244 x 542 mm
- Dimensions Rack: 132 x 440 x 460 mm (mounting kit to be purchased separately)- Tower dimensions (+ pedestal): 450 x 304 x 460 mm
-Height:89 mm-Width:432 mm-Depth:490 mm-Rack Height2U
-Height:43.2mm-Width:438mm-Depth:509mm
-Height:188cm-Width:80mm-Depth:249mm
(1)
(91)
(9)
(5)
(16)
(4)
(54)
(2)
(8)
(37)
(13)
(7)
(12)
(10)
(39)
(22)
(3)